SPECTRA MAX GEMINI XS MICROPLATE FLUORO METER 판매합니다 상태양호 연락처:011-354-6248
Microplate Spectrofluorometer
The Gemini XPS microplate spectrofluorometer allows for fast high-sensitivity measurements as required by most of today's fluorescence-based assays. Cellular and molecular binding studies DNA quantitation drug screening and SNP genotyping analysis all require a high degree of sensitivity. The Gemini XPS system offers a flexible filter-free environment allowing the determination of optimal excitation and emission settings in 1.0 nm increments providing the best level of sensitivity for variable assay conditions.
applications
Cellular and molecular binding studies Nucleic acid quantitation Cytoxicity assays SNP genotype detection and molecular beacons Enzyme activity CatchPoint® cAMP Assay Kit
features
Dual Monochromators—The right pair of excitation and emission wavelengths is always available because the dual monochromators allow the selection of any wavelength in 1 nm increments. New fluorophores can easily be evaluated without purchasing additional filters.
Wavelength Scanning—The most sensitive results are achieved by using optimal excitation and emission wavelengths. Literature wavelengths are often based on results from wavelength-limited filter-based readers. Wavelength scanning ensures that the most sensitive assay conditions are used.
Well Scanning—Gemini XPS can report a single point from the well center or multiple data points from large well tissue culture plates. This provides high sensitivity for cell-based assays.
Auto PMT Gain—Because a single microplate often presents a range of fluorescence intensities greater than three orders of magnitude Gemini XPS features “Auto PMT Gain” to avoid saturating the photomultiplier tube. The signal is calibrated against an internal standard so the reported RFU values of individual samples can be accurately compared.
Gemini XPS
Microplate Spectrofluorometer
The Gemini XPS microplate spectrofluorometer allows for fast high-sensitivity measurements as required by most of today's fluorescence-based assays. Cellular and molecular binding studies DNA quantitation drug screening and SNP genotyping analysis all require a high degree of sensitivity. The Gemini XPS system offers a flexible filter-free environment allowing the determination of optimal excitation and emission settings in 1.0 nm increments providing the best level of sensitivity for variable assay conditions.
applications
Cellular and molecular binding studies Nucleic acid quantitation Cytoxicity assays SNP genotype detection and molecular beacons Enzyme activity CatchPoint® cAMP Assay Kit
features
Dual Monochromators—The right pair of excitation and emission wavelengths is always available because the dual monochromators allow the selection of any wavelength in 1 nm increments. New fluorophores can easily be evaluated without purchasing additional filters.
Wavelength Scanning—The most sensitive results are achieved by using optimal excitation and emission wavelengths. Literature wavelengths are often based on results from wavelength-limited filter-based readers. Wavelength scanning ensures that the most sensitive assay conditions are used.
Well Scanning—Gemini XPS can report a single point from the well center or multiple data points from large well tissue culture plates. This provides high sensitivity for cell-based assays.
Auto PMT Gain—Because a single microplate often presents a range of fluorescence intensities greater than three orders of magnitude Gemini XPS features “Auto PMT Gain” to avoid saturating the photomultiplier tube. The signal is calibrated against an internal standard so the reported RFU values of individual samples can be accurately compared.
SpectraTest FL1 Optical Validation Package Qualify the fluorescence performance of the Gemini EM and Gemini XPS readers by testing the specifications that are absolutely critical to compliance. Twelve different automated tests are provided.
SoftMax Pro® software included with every Gemini XPS SoftMax Pro allows you to select excitation and emission values from the literature and simply input their values for the monochromator settings. If you don't know the recommended wavelengths for the fluorophore of interest you can easily scan both excitation and emission spectra and determine the optimal settings. It really is that easy.
No hardware changes of any kind are required to change modes of operation from standard fluorescence to luminescence or well-scanning. All you have to do is make the selection in SoftMax Pro software with the click of a mouse.
engineered for superior performance and reliability
Figure 1. Gemini XPS optics diagram.
Gemini's dual monochromator design — an excitation monochromator (A) and emission monochromator (B) — allows user-defined variable wavelength settings. A high-powered xenon flash lamp (C) maximizes excitation energy. It sends light through a movable scanning grating (D) which selects the desired excitation wavelength. The light is passed through 1 mm fiber optic bundles (E) to elliptical focusing mirrors (F) that maximize light collection efficiency for superior sensitivity and send the beam to a microplate well (G). If fluorescent molecules are present the light of the emission wavelength is emitted back out to focusing mirrors (H) that direct the light through 4 mm fiber optic bundles (J) to the emission scanning grating (K). The desired wavelength of light is then detected by the photomultiplier tube or PMT (L). The PMT passes the fluorescence signal through the Gemini's electronics creating the signals that result in data points collected by SoftMax Pro software.
Specifications**
general specifications Dimensions (in.) 8.6 (H) x 22.8 (W) x 15 (D)