MILTON ROY SPECTRONIC 501
1. MILTON ROY SPECTRONIC 501 VISIBLE SPECTROPHOTOMETER MACHINE POWERS UP AND SAYS "SELF TEST" THEN SAYS "GOING TO 537 NM 0.125C.MILTON ROY SPECTRONIC 501/601 SPECTROPHOMETERS
The SPECTRONIC 501 visible-wavelength-range and SPECTRONIC601 UV/Visible single-beam narrow bandpass [less than 5 nm] spectrophotometers provide reliable results with microprocessor controlled efficiency.
Instrumental capability makes it particularly useful in the basic research lab or a high output laboratory (industrial quality control toxicology or clinical areas).
Basic design highlights include microprocessor control with a dual function keyboard and ful alphanumeric display test parameter storage the ability to flag out-of-limits readings selectable signal averaging a programmable lamp-change wavelength feature (601 only) an auto zero feature and an auto "go to wavelength" feature.
Both are analog recorder compatible; each comes with the RS-232C interface permitting computer control and hard copy documentation for QA/QC procedures.
The advanced optical system ensures photometric accuracy and reliability.
Optics incorporate toroidal mirrors a replicated holographic grating a tungsten-halogen lamp a deuterium (601 only) source lamp. Silicone dioxide coated optical surface reduced placement frequency.
Make use of the Lamp Saver feature and extended lamp life by selecting a lower lamp intensity for low absorbance samples.
The detector is a solid-state silicone photocell.
Modular design lets you configure the SPECTRONIC 501/601 to meet your present requirements and yet retain future expansion and automation capabilities.
The optional Accessory Control Module controls all automated sampling accessories (flow-thru cell automatic samplers for up to 114 samples or a water-jacketed six potion automatic cell positioner ).
Pre-set sampling programs (standard curve end point kinetics multiple wavelength absorbance ratio ect.) are resident in six APPLIPAK cartridges that plug into the Control Module.
WAVELENGTH RANGE: 325-999 nm for SPECTRONIC 501 195-999 nm for SPECTRONIC 601 BANDPASS: less than 5nm spectral slit width WAVELENGTH ACCURACY: +1.0 nm WAVELENGTH REPRODUCIBILITY: +0.5 nm STRAY RADIANT ENERGY: less than 0.05% at 220 and 340 nm PHOTOMETRIC RANGE: -0.1 to 0 3.0A 0.0 to 125%T -9999 to 9999 Conc. PHOTOMETRIC DRIFT: +0.003 A/hr. near 0A PHOTOMETRIC ACCURACY TRANMITTANCE: +0.25%T OVER 0-100%T ABSORBANCE: +0.003A at 0-0.5A; +0.005A at 0.5-1.0+1% of reading at 1-2A; +2% of reading at 2-3A SAMPLE COMPARTMENT DIMENSION (WxHxD):10.6x10.2x17.1cm (4.2x4.6x6.75")OVERALL DIMENSION (WxHxD): 44.5x19.7x49cm (17.5x7.75x19.3") WEIGHT: 15.9kg (35lbs.)To see a picture of this lab equ. click on photo click here